GPC130 Commercial/ GPM130 Medical
130 Watt Global Performance Switchers
FEATURES:
? Wide-range ac input 85-264 Vac
? 2-year warranty
? Commercial Approved to UL1950, IEC950,
EN60950 and CSA22.2-234 L3
? Medical Approved to UL2601-1, IEC601-1 and
CSA22.2 No. 601
? Conducted EMI exceeds FCC Class B and CISPR 22
Class B (Commercial models) and CISPR 11 Class B
(Medical models)
?
marked to LVD
SPECIFICATIONS:
Ac Input
85-264 Vac, 47-63 Hz single phase.
Input Current
Maximum input current at 120 Vac, 60 Hz with full rated output
Power Fail
TTL- or CMOS-compatible output goes low (< 0.5V) 5 ms
before output voltage drops more than 4% below nominal
voltage upon loss of ac power. The signal is factory set to
trip on 84 to 94Vac brown-out depending upon incoming line
impedance and distortion. Other settings are available to the
user through adjustment of built-in potentiometer.
load: 3.5 A
Output Noise
Hold-Up Time
20 ms minimum from loss of ac input at full load, nominal line
(115 Vac).
Output Power
100 W continuous, 165 W peak; 130 W with 26 cfm air flow. Peak
ratings are for 60 s maximum duration, 10% duty cycle. During
peak load condition, output regulation may exceed total
regulation limits.
Overload Protection
Fully protected against short circuit and output overload. Short
circuit protection is cycling type power limit on outputs 1 & 2;
foldback type on outputs 3 & 4. Recovery after fault is automatic.
See output ratings chart for additional notes or conditions.
Overvoltage Protection
Main outputs: 124% ± 12% typical.
Efficiency
70% at full rated load, nominal input voltage, depending on model
and load distribution.
Turn-on Time
Less than 1 second at 120 Vac, 25 ° C (inversely proportional to
input voltage and thermistor temperature).
0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential mode.
Measured with noise probe directly across output terminals of
the power supply.
Transient Response
Main output — 500μSec typical response time for return to within
0.5% of final value for a 50% load step change. ? i/ ? t<0.2 A/μs.
Maximum voltage deviation is 3.5%. Startup/shutdown overshoot
less than 3%.
Remote Sense
Provided as a standard feature on output 1.
Voltage Adjustment
Built-in potentiometer adjusts voltage ±5% on outputs 1 & 2.
Overload Protection
Factory set to begin power limiting at approximately 170 W.
EMI/EMC Compliance
All models include built-in EMI filtering to meet the following
emissions requirements:
EMI SPECIFICATIONS COMPLIANCE LEVEL
Conducted Emissions GPC130 EN55022 Class B; FCC Class B
Conducted Emissions GPM130 EN55022 Class B; FCC Class B
Static Discharge EN61000-4-2, 6 kV contact, 8 kV air
RF Field Susceptibility EN61000-4-3, 3 V/meter
Input Protection
Fast Transients/Bursts
EN61000-4-4, 2 kV, 5 kHz
Internal ac fuse provided. Designed to blow only if a catastrophic
Surge Susceptibility EN61000-4-5, 1 kV diff., 2 kV com.
failure occurs in the unit.
Commercial Leakage Current
Inrush Current
Inrush is limited by internal thermistors. Inrush at 240 Vac under
cold start conditions will not exceed 34 A.
Temperature Coefficient
0.03%/ ° C typical on all outputs.
Thermal Shutdown
Provided as a standard feature. Designed to protect unit from
prolonged overtemperature.
Environmental
Designed for 0 to 50 ° C operation at full rated output power;
derate output current and total output power by 2.5% per ° C
above 50 ° C. See Environmental and Packaging Specifications
on next page.
0.7 mA 254 Vac @ 60 Hz input.
Commercial Safety
Approved to UL1950, CSA22.2 No. 234 Level 3, IEC950 and
EN60950. UL file #E135803 commercial; CSA #LR46516 all
models. The output(s) are intended for safety earthed Signal
Output and Intermediate Circuits only. All dc outputs are SELV
under normal and single fault conditions.
Medical Leakage Current
35 μA 254 Vac @ 60 Hz input.
Medical Safety
Approved to UL2601, CSA22.2 No. 601 Level 3 and IEC601. UL
file E116994; CSA #LR46516. The output(s) are intended for
safety earthed Signal Output and Intermediate Circuits only. The
output(s) are not acceptable for patient connection without
additional isolation. All dc outputs are SELV under normal and
single fault conditions.
Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033
54
800-235-5929 ? 805-486-4565 ? FAX 805-487-8911 ? www.condorpower.com
相关PDF资料
GPC140-12G POWER SUPPLY SWITCHER 140W 12V
GPC200F POWER SUPPLY SWITCHER 200W QUAD
GPC225-5G POWER SUPPLY SWITCHER 225W 5V
GPC40DG POWER SUP SWITCHER 40W TRIPLE
GPC41-15G POWER SUPPLY SWITCHER 40W 15V
GPC50AG POWER SUP SWITCHER 50W TRIPLE
GPC55-12G POWER SUPPLY SWITCHER 55W 12V
GPC80-24G POWER SUPPLY SWITCHER 80W 24V
相关代理商/技术参数
GPC130C-T 功能描述:线性和开关式电源 130W +5/+12/-15/+15V TERM RoHS:否 制造商:TDK-Lambda 产品:Switching Supplies 开放式框架/封闭式:Enclosed 输出功率额定值:800 W 输入电压:85 VAC to 265 VAC 输出端数量:1 输出电压(通道 1):20 V 输出电流(通道 1):40 A 商用/医用: 输出电压(通道 2): 输出电流(通道 2): 安装风格:Rack 长度: 宽度: 高度:
GPC130D 功能描述:线性和开关式电源 130W +5/+24/-12/+12V RoHS:否 制造商:TDK-Lambda 产品:Switching Supplies 开放式框架/封闭式:Enclosed 输出功率额定值:800 W 输入电压:85 VAC to 265 VAC 输出端数量:1 输出电压(通道 1):20 V 输出电流(通道 1):40 A 商用/医用: 输出电压(通道 2): 输出电流(通道 2): 安装风格:Rack 长度: 宽度: 高度:
GPC130DG 功能描述:线性和开关式电源 130W +5/+24/-12/+12V RoHS:否 制造商:TDK-Lambda 产品:Switching Supplies 开放式框架/封闭式:Enclosed 输出功率额定值:800 W 输入电压:85 VAC to 265 VAC 输出端数量:1 输出电压(通道 1):20 V 输出电流(通道 1):40 A 商用/医用: 输出电压(通道 2): 输出电流(通道 2): 安装风格:Rack 长度: 宽度: 高度:
GPC130D-G 制造商:SL Power Electronics / Condor 功能描述:
GPC130E 功能描述:线性和开关式电源 130W +5/+24/-15/+15V RoHS:否 制造商:TDK-Lambda 产品:Switching Supplies 开放式框架/封闭式:Enclosed 输出功率额定值:800 W 输入电压:85 VAC to 265 VAC 输出端数量:1 输出电压(通道 1):20 V 输出电流(通道 1):40 A 商用/医用: 输出电压(通道 2): 输出电流(通道 2): 安装风格:Rack 长度: 宽度: 高度:
GPC130EG 功能描述:线性和开关式电源 130W +5/+24/-15/+15V RoHS:否 制造商:TDK-Lambda 产品:Switching Supplies 开放式框架/封闭式:Enclosed 输出功率额定值:800 W 输入电压:85 VAC to 265 VAC 输出端数量:1 输出电压(通道 1):20 V 输出电流(通道 1):40 A 商用/医用: 输出电压(通道 2): 输出电流(通道 2): 安装风格:Rack 长度: 宽度: 高度:
GPC140 制造商:SLPOWER 制造商全称:SL Power Electronics 功能描述:140 Watt Global Performance Switchers
GPC140-12 功能描述:线性和开关式电源 140W 12V @ 11.7A RoHS:否 制造商:TDK-Lambda 产品:Switching Supplies 开放式框架/封闭式:Enclosed 输出功率额定值:800 W 输入电压:85 VAC to 265 VAC 输出端数量:1 输出电压(通道 1):20 V 输出电流(通道 1):40 A 商用/医用: 输出电压(通道 2): 输出电流(通道 2): 安装风格:Rack 长度: 宽度: 高度: